Forced circulation systems - pressurized

CPC 1506

Evacuated tube collector with CPC-reflector - 6 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation 
    • Flat roof / wall installation


    Note:
    The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1506
No. of Evacuated Tubes   6
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 0.70 x 1.64 x 0.1
Gross surface area 1.15
Aperture area 1.0
Collector contents l 0.8
Weight kg 19
Max. working overpressure bar 10
Max. stagnation temperature °C 272
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Thermal shock test ITW test 06COL513/1
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448
EC type examination   Z-IS-DDK-MUC-07-08-100029919-003

CPC 1512

Evacuated tube collector with CPC-reflector - 12 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof / wall installation


    Note:
    The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1512
No. of Evacuated Tubes   12
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 1.39 x 1.64 x 0.1
Gross surface area 2.28
Aperture area 2.0
Collector contents l 1.6
Weight kg 37
Max. working overpressure bar 10
Max. stagnation temperature °C 272
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Thermal shock test ITW test 06COL513/1
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448
EC type examination   Z-IS-DDK-MUC-07-08-100029919-003

CPC 1518

Evacuated tube collector with CPC-reflector - 18 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector

    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof / wall installation


    Note: The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1518
No. of Evacuated Tubes   18
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 2.08 x 1.64 x 0.1
Gross surface area 3.41
Aperture area 3.0
Collector contents l 2.4
Weight kg 54
Max. working overpressure bar 10
Max. stagnation temperature °C 272
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Thermal shock test ITW test 06COL513/1
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448
EC type examination   Z-IS-DDK-MUC-07-08-100029919-003

U 1521

Evacuated tube collector without CPC-reflector - 21 evacuated tubes
for water heating, series connection

  • Pipe material: Copper

    Scope of delivery: Fully pre-assembled unit comprising

    •  Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof
    • Horizontal installation

Specification

Series   U1521
No. of Evacuated Tubes   21
η (Aperture), DIN 4757-4 or EN 12975 % 74.5
c1 with wind, in relation to aperture W/(m²k) 2.007
c2 with wind, in relation to aperture W/(m²k²) 0.005
Yield forecast kWh/m²a 780
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 619
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 1.45 x 1.64 x 0.1
Gross surface area 2.32
Aperture area 1.33
Collector contents l 2.5
Weight kg 51
Max. working overpressure bar 10
Max. stagnation temperature °C 220
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Thermal shock test ITW test 06COL517
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448
EC type examination   Z-ISDDK-MUC-07-08-100029919-003

Evacuated heat pipe collector

  • for water, space and process heating and solar cooling.

    Scope of delivery

    Fully pre-assembled unit comprising
    • 12, 16, 20, 24 or 30 evacuated heat pipes,
    • Mainfold with direct flow heat conduction unit and dry tube connection.

    Collector are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated heat pipe collector.

    Installations types
    • Pitched roof, flat roof, on-wall.

Series   LN 47-1500-16 LN 47-1500-20 LN 47-1800-16 LN 47-1800-20
No. of evacuated tubes   16 20 16 20
η in relation to aperture, EN 1297 % 68.1 68.1 68.1 500
a1 with wind, in relation to aperture W/(m²k) 1.60 1.60 1.60 1.60
a2 with wind, in relation to aperture W/(m²k²) 0.006 0.006 0.006 0.006
Grid dimensions (length x height x depth) m 1.64x1.15x0.1.4 1.64x1.75x0.14 1.94x1.29x0.14 1.94x1.59x0.14
Gross area 1.89 2.86 2.5 3.08
Aperture area 1.08 1.35 1.61 2.02
Collector contents l 1.82 1.02 1.94 1.17
Weight kg 36 45 53 66
Max. operating pressure Mpa 0.7 0.7 0.7 0.7
Max. stagnation temperature.1) °C 230 230 230 230
Connection diameter, compression fitting mm 22 22 22 22
Glass tube material   Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3
Selective absorber coating material   SS-AL-N/Cu SS-AL-N/Cu SS-AL-N/Cu SS-AL-N/Cu
Glass tube (Ø ext./Ø int./wall thickn./tube lgth.)   47/37/1.6/1500 47/37/1.6/1500 58/47/1.6/1800 58/47/1.6/1800
Colour (aluminium frame profile, anodised)   Aluminum grey Aluminum grey Aluminum grey Aluminum grey
  • CPC OEM XL Evacuated tube collector

    for water, space and process heating and solar cooling.

    Available in two different lenghts:1.64m and 2.05m

    Scope of delivery

    Fully pre-assembled unit comprising
    • 14, 18 or 21 evacuated tubes based on the thermos flask principle,
    • Mainfold with direct flow heat conduction unit and dry tube connection,
    • CPC-reflector.

    Collector are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.


    Installations types
    • Pitched roof, flat roof, on-wall.

SPECIFICATION

Series   CPC OEM XL 1514 CPC OEM XL 1521 CPC OEM XL 1914 CPC OEM XL 1918 CPC OEM XL 1921
No. of Evacuated Tubes   14 21 14 18 21
η in relation to aperture, EN 12975 % 64.2 64.2 64.2 64.2 64.2
a1 with wind, in relation to aperture W/(m²k) 0.89 0.89 0.89 0.89 0.89
a2 with wind, in relation to aperture W/(m²k²) 0.001 0.001 0.001 0.001 0.001
Yield forecast (location Würzburg, Germany, reference area 3m²) kWh/m²a 651 651 651 651 651
Yield forecast (location Würzburg, Germany, reference area 5m²) kWh/m²a 589 589 589 589 589
Grid dimensions (length x height x depth) m 1.62 x 1.64 x 0.1 2.42 x 1.64 x 0.1 1.62 x 2.05 x 0.1 2.08 x 2.05 x 0.1 2.42 x 2.05 x 0.1
Gross surface area 2.62 3.92 3.34 4.28 5
Aperture area 2.33 3.49 2.97 3.84 4.46
Collector contents l 1.9 2.7 2.22 2.85 3.33
Weight kg 41.4 61.2 47.4 61 71.2
Max. working overpressure bar 10 10 10 10 10
Max. stagnation temperature °C 272 272 272 272 272
Connection diameter, compression fitting mm 15 15 15 15 15
Sensor sleeve mm 6 6 6 6 6
Collector material   Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride Aluminium nitride Aluminium nitride Aluminium nitride Aluminium nitride
Glass tube (Ø ext./Ø int./wall thickn./tube lgth.) mm 47/37/1.6/1500 47/37/1.6/1500 47/37/1.6/1500 47/37/1.6/1500 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey Aluminium grey Aluminium grey Aluminium grey Aluminium grey
Colour (plastic parts)   Black Black Black Black Black
Thermal shock test ITW test number 06COL513/1 06COL513/1 06COL513/1 06COL513/1 06COL513/1
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448 435/142448 435/142448 435/142448 435/142448
EC type examination   Z-IS-DDK-MUC-07-08-100029919-003 Z-IS-DDK-MUC-07-08-100029919-003 Z-IS-DDK-MUC-07-08-100029919-003 Z-IS-DDK-MUC-07-08-100029919-003 Z-IS-DDK-MUC-07-08-100029919-003

Flat plate collector

  • for water, space and process heating with 60℃ ~ 80℃ temperature requirement.

    Scope of delivery

    • Fully pre-assembled collector unit 

    Installation types

     

    • Pitched roof, flat roof, on-wall

Series FP2000
Collector dimensions (L x H x D) 2000 x 1000 x 80mm
Gross surface area 2m2
Aperture area 1.88m2
Absorber coating material Blue Titanium / Black Chrome
Absorber coating thickness 0.20~0.26mm
Absorber sheet material Aluminum
Absorber sheet thickness 0.3mm
Absorption rate ≥92%
Emission rate ≤5.8%
Header tube number 2
Header tube size/ material φ22 x 0.6mm / Copper
Riser tube number 8
Riser tube size/ material φ10 x 0.5 mm/ Copper
Medium volume 2.1L
Cover material Low iron tempered textured glass
Cover thickness 3.2mm
Cover transmittance ≥90%
Insulation material Polyster / Fiberglass
Insulation thickness 35mm
Frame material/ thickness Aluminum / ≥1.0mm
Back plate material/ thickness Galvanized sheet / 0.3mm
Test pressure 1.2Mpa
Max. working pressure 0.8Mpa
Net weight 36kg
Collector effiency η0 78%
Max. stagnation temperature 186℃

For further information please contact our sales team.