Forced circulation systems - pressurized

CPC 1506

Evacuated tube collector with CPC-reflector - 6 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation 
    • Flat roof / wall installation


    Note:
    The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1506
No. of Evacuated Tubes   6
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 0.70 x 1.64 x 0.1
Gross surface area 1.15
Aperture area 1.0
Collector contents l 0.8
Weight kg 19
Max. working overpressure bar 10
Max. stagnation temperature °C 272
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Testing report No. ITW test 17COL1383

CPC 1512

Evacuated tube collector with CPC-reflector - 12 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof / wall installation


    Note:
    The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1512
No. of Evacuated Tubes   12
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 1.39 x 1.64 x 0.1
Gross surface area 2.28
Aperture area 2.0
Collector contents l 1.6
Weight kg 37
Max. working overpressure bar 10
Max. stagnation temperature °C 272
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Testing report No. ITW test 17COL1383

CPC 1518

Evacuated tube collector with CPC-reflector - 18 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector

    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof / wall installation


    Note: The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1518
No. of Evacuated Tubes   18
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 2.08 x 1.64 x 0.1
Gross surface area 3.41
Aperture area 3.0
Collector contents l 2.4
Weight kg 54
Max. working overpressure bar 10
Max. stagnation temperature °C 272
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Testing report No. ITW test 17COL1383

U 1521

Evacuated tube collector without CPC-reflector - 21 evacuated tubes
for water heating, series connection

  • Pipe material: Copper

    Scope of delivery: Fully pre-assembled unit comprising

    •  Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof
    • Horizontal installation

Specification

Series   U1521
No. of Evacuated Tubes   21
η (Aperture), DIN 4757-4 or EN 12975 % 74.5
c1 with wind, in relation to aperture W/(m²k) 2.007
c2 with wind, in relation to aperture W/(m²k²) 0.005
Yield forecast kWh/m²a 780
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 619
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 1.45 x 1.64 x 0.1
Gross surface area 2.32
Aperture area 1.33
Collector contents l 2.5
Weight kg 51
Max. working overpressure bar 10
Max. stagnation temperature °C 220
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Thermal shock test ITW test 17COL1382Q

Evacuated heat pipe collector

  • for water, space and process heating and solar cooling.

    Scope of delivery

    Fully pre-assembled unit comprising
    • 12, 16, 20, 24 or 30 evacuated heat pipes,
    • Mainfold with direct flow heat conduction unit and dry tube connection.

    Collector are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated heat pipe collector.

    Installations types
    • Pitched roof, flat roof, on-wall.

Series   R58-1816 R58-1818 R15-1820 R58-1824 R58-1830
No. of evacuated tubes   16 18 20 24 30
η0 in relation to aperture area, ISO 9806 % 74.5 74.5 74.5 74.5 74.5
Grid dimensions (length x height x depth) mm 1970x1251x161 1970x1401x161 1970x1551x161 1970x1851x161 1970x2301x161
Gross area 2.46 2.76 3.06 3.65 4.53
Aperture area 1.62 1.82 2.03 2.43 3.04
Collector contents L 0.854 0.961 1.069 1.285 1.608
Weight kg 53 58 67 81 99
Max. working pressure Mpa 0.8 0.8 0.8 0.8 0.8
Max. stagnation temperature.1) °C 267.6 267.6 267.6 267.6 267.6
Connection diameter, compression fitting mm 22 22 22   22
Glass tube material   Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3   Borosilicate glass 3.3
Selective absorber coating material   SS-AL-N/Cu SS-AL-N/Cu SS-AL-N/Cu   SS-AL-N/Cu
Glass tube (Ø ext./Ø int./wall thickn./tube lgth.)   58/47/1.6/1800 58/47/1.6/1800 58/47/1.6/1800 58/47/1.6/1800 58/47/1.6/1800
Colour (aluminium frame profile, anodised)   Aluminum grey Aluminum grey Aluminum grey Aluminum grey Aluminum grey

CPC OEM XL collector

  • for water, space and process heating and solar cooling.

    Available in two different lenghts:1.64m and 2.05m

    Scope of delivery

    Fully pre-assembled unit comprising
    • 14, 18 or 21 evacuated tubes based on the thermos flask principle,
    • Mainfold with direct flow heat conduction unit and dry tube connection,
    • CPC-reflector.

    Collector are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.


    Installations types
    • Pitched roof, flat roof, on-wall.

SPECIFICATION

Series   CPC XL 1514 CPC XL 1521 CPC XL 1914 CPC XL 1918 CPC XL 1921
No. of Evacuated Tubes   14 21 14 18 21
η in relation to aperture, EN 12975 % 64.2 64.2 64.2 64.2 64.2
a1 with wind, in relation to aperture W/(m²k) 0.89 0.89 0.89 0.89 0.89
a2 with wind, in relation to aperture W/(m²k²) 0.001 0.001 0.001 0.001 0.001
Yield forecast (location Würzburg, Germany, reference area 3m²) kWh/m²a 651 651 651 651 651
Yield forecast (location Würzburg, Germany, reference area 5m²) kWh/m²a 589 589 589 589 589
Grid dimensions (length x height x depth) m 1.62 x 1.64 x 0.1 2.42 x 1.64 x 0.1 1.62 x 2.05 x 0.1 2.08 x 2.05 x 0.1 2.42 x 2.05 x 0.1
Gross surface area 2.62 3.92 3.34 4.28 5
Aperture area 2.33 3.49 2.97 3.84 4.46
Collector contents l 1.9 2.7 2.22 2.85 3.33
Weight kg 41.4 61.2 47.4 61 71.2
Max. working overpressure bar 10 10 10 10 10
Max. stagnation temperature °C 345 345 345 345 345
Connection diameter, compression fitting mm 15 15 15 15 15
Sensor sleeve mm 6 6 6 6 6
Collector material   Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride Aluminium nitride Aluminium nitride Aluminium nitride Aluminium nitride
Glass tube (Ø ext./Ø int./wall thickn./tube lgth.) mm 47/37/1.6/1500 47/37/1.6/1500 47/37/1.6/1920 47/37/1.6/1920 47/37/1.6/1920
Colour (aluminium frame profile, anodised)   Aluminium grey Aluminium grey Aluminium grey Aluminium grey Aluminium grey
Colour (plastic parts)   Black Black Black Black Black
Thermal shock test ITW test number 17COL1384 17COL1384 17COL1384 17COL1384 17COL1384

LPC collector (open-loop)

  • for water, space and process heating with 60℃ ~ 80℃ temperature requirement.

    Scope of delivery

    • Vacuum tubes based on thermos flask principle
    • manifold

    Installation types

    • Pitched roof, flat roof

     

     

Series   LPC 58-1825 LPC 58-1830 LPC 58-1850
Collector dimensions (L x H x D) mm 2160x1935x158 2560x1935x158 3670x2160x158
Gross surface area m2 4 4.8 7.6
Aperture area m2 2.46 2.95 4.92
Collector efficiency % 57 57 57
Collector contents l 83 100 160
Number of tubes   25 30 50
Vacuum tubes mm φ58x1800 φ58x1800 φ58x1800
Gap between the tubes mm 80 80 80
Tube installation   Vertical Vertical Horizontal
Inner tank material / mm SUS304/0.5 SUS304/0.5 SUS304/0.5
Outer tank material Aluminum alloy/SUS304 Aluminum alloy/SUS304 Aluminum alloy/SUS304
Insulation material / mm Polyurethane /50 Polyurethane /50 Polyurethane /50
Weight kg 146 175 225
Max. working pressure bar 0.5 0.5 0.5