Forced circulation systems - pressurized

CPC 1506

Evacuated tube collector with CPC-reflector - 6 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation 
    • Flat roof / wall installation


    Note:
    The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1506
No. of Evacuated Tubes   6
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 0.70 x 1.64 x 0.1
Gross surface area 1.15
Aperture area 1.0
Collector contents l 0.8
Weight kg 19
Max. working overpressure bar 10
Max. stagnation temperature °C 345
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Testing report No. ITW test 17COL1383

CPC 1512

Evacuated tube collector with CPC-reflector - 12 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof / wall installation


    Note:
    The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1512
No. of Evacuated Tubes   12
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 1.39 x 1.64 x 0.1
Gross surface area 2.28
Aperture area 2.0
Collector contents l 1.6
Weight kg 37
Max. working overpressure bar 10
Max. stagnation temperature °C 345
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Testing report No. ITW test 17COL1383

CPC 1518

Evacuated tube collector with CPC-reflector - 18 evacuated tubes
for water, space and process heating, series connection

  • Pipe material: Copper

    Scope of delivery:
    Fully pre-assembled unit comprising

    • Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection
    • CPC-reflector

    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof / wall installation


    Note: The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°.

Specification

Series   CPC1518
No. of Evacuated Tubes   18
η (Aperture), DIN 4757-4 or EN 12975 % 64.2
c1 with wind, in relation to aperture W/(m²k) 0.89
c2 with wind, in relation to aperture W/(m²k²) 0.001
Yield forecast kWh/m²a 651
(location Würzburg, Germany, reference area 3m²)    
Yield forecast kWh/m²a 589
(location Würzburg, Germany, reference area 5m²)    
Grid dimensions (length x height x depth) m 2.08 x 1.64 x 0.1
Gross surface area 3.41
Aperture area 3.0
Collector contents l 2.4
Weight kg 54
Max. working overpressure bar 10
Max. stagnation temperature °C 345
Connection diameter, clamping ring mm 15
Sensor sleeve mm 6
Collector material   AI / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) mm 47/37/1.6/1500
Colour (aluminium frame profile, anodised)   Aluminium grey
Colour (plastic parts)   Black
Testing report No. ITW test 17COL1383
  • Pipe material: Copper

    Scope of delivery: Fully pre-assembled unit comprising

    •  Evacuated tubes based on the thermos flask principle
    • Manifold with direct flow heat conduction unit and dry tube connection


    Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

    Installation types:

    • On-roof installation
    • Flat roof
    • Horizontal installation

CPC XL collector

  • for water, space and process heating and solar cooling.

    Available in two different lenghts:1.64m and 2.05m

    Scope of delivery

    Fully pre-assembled unit comprising
    • 14, 18 or 21 evacuated tubes based on the thermos flask principle,
    • Mainfold with direct flow heat conduction unit and dry tube connection,
    • CPC-reflector.

    Collector are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.


    Installations types
    • Pitched roof, flat roof, on-wall.

SPECIFICATION

Series   CPC XL 1514 CPC XL 1521 CPC XL 1914 CPC XL 1918 CPC XL 1921
No. of Evacuated Tubes   14 21 14 18 21
η in relation to aperture, EN 12975 % 64.2 64.2 64.2 64.2 64.2
a1 with wind, in relation to aperture W/(m²k) 0.89 0.89 0.89 0.89 0.89
a2 with wind, in relation to aperture W/(m²k²) 0.001 0.001 0.001 0.001 0.001
Yield forecast (location Würzburg, Germany, reference area 3m²) kWh/m²a 651 651 651 651 651
Yield forecast (location Würzburg, Germany, reference area 5m²) kWh/m²a 589 589 589 589 589
Grid dimensions (length x height x depth) m 1.62 x 1.64 x 0.1 2.42 x 1.64 x 0.1 1.62 x 2.05 x 0.1 2.08 x 2.05 x 0.1 2.42 x 2.05 x 0.1
Gross surface area 2.62 3.92 3.34 4.28 5
Aperture area 2.33 3.49 2.97 3.84 4.46
Collector contents l 1.9 2.7 2.22 2.85 3.33
Weight kg 41.4 61.2 47.4 61 71.2
Max. working overpressure bar 10 10 10 10 10
Max. stagnation temperature °C 345 345 345 345 345
Connection diameter, compression fitting mm 15 15 15 15 15
Sensor sleeve mm 6 6 6 6 6
Collector material   Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE Al / Cu / glass / Silicone / PBT / EPDM / TE
Glass tube material   Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3 Borosilicate glass 3.3
Selective absorber coating material   Aluminium nitride Aluminium nitride Aluminium nitride Aluminium nitride Aluminium nitride
Glass tube (Ø ext./Ø int./wall thickn./tube lgth.) mm 47/37/1.6/1500 47/37/1.6/1500 47/37/1.6/1920 47/37/1.6/1920 47/37/1.6/1920
Colour (aluminium frame profile, anodised)   Aluminium grey Aluminium grey Aluminium grey Aluminium grey Aluminium grey
Colour (plastic parts)   Black Black Black Black Black
Thermal shock test ITW test number 17COL1384 17COL1384 17COL1384 17COL1384 17COL1384